Forward tipping dumper daily pre-use check sheet
The 34 checks an operator makes before using a forward tipping dumper each day, on one printable sheet that covers a week. Free to print and use, no account needed.

The checks on the sheet
Pre-start and walk-around
- Handbook on machine and current weekly inspection report available
Verify the operator handbook is with the machine and a current weekly inspection report is in date.
- General condition and cleanliness (including cab if fitted)
- No evidence of oil leaks
Check hydraulic cylinders, fittings, valves, axles, wheel hubs and gearbox.
- Wheels and tyres — rims, nut security, tread and sidewalls
Check for bent rims and nut security; worn tread, cuts and damage to side walls and tread.
- Tyre pressures correct (gauge check)
- Hydraulic rams, hoses and pipes — condition and security
- ROPS bar — condition
No cracks, no unauthorised modifications.
- Operator station / cab condition and ROPS/FOPS mounting
- Cab windows — clean and undamaged
- No cracked or unauthorised welding
- Guards, cowlings and fasteners — in place and secure
- Decals, labels and manufacturer's rating plate — legible
- Lights, mirrors, CCTV and other vision aids
Lubricants and fluids
- Engine oil level
- Transmission oil level
- Coolant level
Check when cool. Never open a hot radiator cap.
- Battery — secure, terminals clean, electrolyte (if applicable)
- Brake fluid level
- Hydraulic oil level
- Fuel level and additives (AdBlue etc.)
Other engine checks
- Fan belt deflection within tolerance
- Air filter indicator in normal range
- Visual check of all engine components — no issues
Running checks
- Parking brake function
- Footbrake function
- Steering function
- Skip tipping function
- Transmission function
- All gauges, instruments, horn and hour meter functional
- All lights, indicators and beacon(s) operational
- Heater, defroster and wipers function correctly (if fitted)
- Seat position and seat belt function
- No unusual noises
Listen during all running checks for knocks, grinding, squeals or hissing.
- All warning devices operational
Includes reversing alarm, warning lights, audible and visual alarms.
PUWER doesn’t itself require a daily check or a written record of one. HSE’s construction guidance does recommend daily checks for some plant, such as dumpers and MEWPs, and a written sheet is the easiest way to show the check was done and a defect was reported. A pre-use check is not the PUWER inspection or the LOLER thorough examination: those are separate, by a competent person, and recorded. What the law requires, with the sources.
These sheets are general guidance, not a substitute for the manufacturer’s instructions, your own risk assessment or a competent person’s inspection. Add anything the manufacturer or the hire company asks you to check.